Signametrics Corp - features

By: Signametrics  06-Dec-2011


MODEL



             
Digits of Resolution 6-1/2 6-1/2 6-1/2 5-1/2 6-1/2 7-1/2 7-1/2
Measurement Rates 0.2/sec - 1000/sec 0.2/sec - 1000/sec 0.2/sec - 1000/sec 2/sec - 115/sec 1/sec - 250/sec 0.2/sec - 1400/sec 0.2/sec - 20,000/sec
               
             
330 mV
3.3 V
33 V
330 V
330 mV
3.3 V
33 V
330 V
330 mV
3.3 V
33 V
330 V
240 mV
2.4 V
24 V
240 V
240 mV
2.4 V
24 V
240 V
240 mV
2.4 V
24 V
240 V
330 V
240 mV
2.4 V
24 V
240 V
330 V
330 mV
3.3 V
33 V
250 V
330 mV
3.3 V
33 V
250 V
330 mV
3.3 V
33 V
250 V
240 mV
2.4 V
24 V
240 V
240 mV
2.4 V
24 V
240 V
240 mV
2.4 V
24 V
240 V
330 V
240 mV
2.4 V
24 V
240 V
330 V

330 Ω
3.3 K Ω
33 K Ω
330 K Ω
3.3 M Ω
33 M Ω
33 Ω
330 Ω
3.3 KΩ
33 KΩ
330 KΩ
3.3 MΩ
33 MΩ
330 MΩ
33 Ω
330 Ω
3.3 KΩ
33 KΩ
330 KΩ
3.3 MΩ
33 MΩ
330 MΩ

240 Ω
2.4 KΩ
24 KΩ
240 KΩ
2.4 MΩ
24 MΩ

240 Ω
2.4 KΩ
24 KΩ
240 KΩ
2.4 MΩ
24 MΩ

240 Ω
2.4 KΩ
24 KΩ
240 KΩ
2.4 MΩ
24 MΩ
24 Ω
240 Ω
2.4 KΩ
24 KΩ
240 KΩ
2.4 MΩ
24 MΩ
240 MΩ

330 Ω
3.3 KΩ
33 KΩ
330 KΩ
33 Ω
330 Ω
3.3 KΩ
33 KΩ
330 KΩ
33 Ω
330 Ω
3.3 KΩ
33 KΩ
330 KΩ

240 Ω
2.4 KΩ
24 KΩ
240 KΩ
2.4 MΩ
24 MΩ

240 Ω
2.4 KΩ
24 KΩ
240 KΩ

240 Ω
2.4 KΩ
24 KΩ
240 KΩ
2.4 MΩ
24 MΩ
24 Ω
240 Ω
2.4 KΩ
24 KΩ
240 KΩ
2.4 MΩ
24 MΩ
3.3 mA
33 mA
330 mA
2.5 A
3.3 mA
33 mA
330 mA
2.5 A
3.3 mA
33 mA
330 mA
2.5 A
2.4 mA
24 mA
240 mA
2.4 A
2.4 mA
24 mA
240 mA
2.4 A
2.4 mA
24 mA
240 mA
2.4 A
240 nA
2.4 µA
24 µA
240 µA
2.4 mA
24 mA
240 mA
2.4 A
3.3 mA
33 mA
330 mA
2.5 A
3.3 mA
33 mA
330 mA
2.5 A
3.3 mA
33 mA
330 mA
2.5 A
2.4 mA
24 mA
240 mA
2.4 A
2.4 mA
24 mA
240 mA
2.4 A
2.4 mA
24 mA
240 mA
2.4 A
2.4 mA
24 mA
240 mA
2.4 A
 
10 nF
100 nF
1 µF
10 µF
100 µF
1 mF
10 mF

10 nF
100 nF
1 µF
10 µF
100 µF
1 mF
10 mF
      1.2 nF
12 nF
120 nF
1.2 µF
12 µF
120 µF
1.2 mF
12 mF
   
33 µH
330 µH
3.3 mH
33 mH
330 mH
3.3 H
      2.4 µH
24 µH
240 µH
2.4 mH
24 mH
240 mH
2.4 H
               
             
    0 to +/- 10.0 V       0 to +/- 10.0 V
ACV source
(0 to 20 V pk-pk)
    2 Hz - 75 kHz       1 Hz - 200 kHz
    120 nA
1.2 µA
12 µA
120 µA
1.2 mA
12 mA
      120 nA
1.2 µA
12 µA
120 µA
1.2 mA
12 mA
Diode V/I characteristics 100nA - 1mA 100nA - 10mA 100nA - 10mA
plus Variable
100nA - 1mA 100nA - 1mA 100nA - 10mA 10nA - 12.5mA
plus Variable
               
               
MODEL



             
auto range, relative
Min/Max, dB and % dev.
On board measurement buffer    
   
       
Pulse width, pos./neg., & duty cycle        
Totalizer/event counter        
Variable threshold timing measure        
Peak to Peak, Crest factor, Median        
Internal DMM temperature sensor        
Settable Reading Interval and Aperture          
High speed range & function change      
Fast RMS          
Component Handler Interface
(high volumen production)
         
Low Frequency RMS            
           
           
           
Load Cells and Strain Gauges stimulus and measurement            
               
             
   
         
         
Voltage & Current limited Resistance measure.          
Leakage measurement with variable V          
Capacitance, in circuit          
     
               
             
External and threshold trigger    
with pre & post data

with pre & post data
Delayed Trigger, External; pre and post trigger data          
               
             

Win 95/98/ME
Win NT/2000/XP
Linux
Windows 7/Vista
     
Plug-and-Play software installation
Language Support:
Visual Basic, C, C++, C#, Delphi, .NET
Package Support:
LabView, LabWindows/CVI, TestPoint, ATEasy, Matlab, VBA & more
Additional Support:
any windows software capable of making calls to a DLL


Other products and services from Signametrics

06-Dec-2011

Switching Cards, Multimeter Scanners, Multiplexers, PCI PXI USB test measurement

Weighing in at less then a pound, and with dimensions of 5'' X 7'' X 1.3'', the SMU4032 is ideal for environments and applications where size, weight, or mobility requirements rule out traditional bench top equipment. The SMU4032 is the only mobile USB switch with instrumentation specifications, making it the only mobile USB switch that enables your 6-1/2 or 7-1/2 digit DMM to deliver its full accuracy.


06-Dec-2011

SMU2064 7-1/2 Digit USB Digital Multimeter, Portable Inductance Measurement Applications

By cutting down on the number of components and connections in your test system, the USB DMM provides a reliable and cost effective automated measurement capabilities, without compromising performance. Automated applications can be configured using Visual Basic, C, C++, LabView, LabWindows/CVI, TestPoint, ATEasy, Matlab, Delphi and more.


06-Dec-2011

Signametrics Corp - dmm

Kit contains:Leads, Probes, Spade Lug, Alligator Clip,Extender Probe, Hook Lead, Pouch. Soft tactile Test Leads with gold tips and straight safety Banana Plugs. DIN trigger / guard connector. SM-PRD, Deluxe DMM probe kit.