Jaguar Shielded Cable - PTFE Insulation

DESCRIPTION: PTFE INSULATED CONDUCTORS (TYPE E), COLOR CODED, CABLED FOR 2 OR MORE CONDUCTORS, BRAIDED, WITH SILVER PLATED COPPER (90% MINIMUM COVERAGE), WITH A SINTERED TAPE WRAPPED OR EXTRUDED FEP JACKET OVERALL.

CONDUCTORS: STRANDED SILVER-PLATED COPPER.

INSULATION: PRIMARY - TFE EXTRUDED PTFE.
JACKET - TFE TAPED PTFE OR FEP EXTRUDED PTFE.

TEMPERATURE RATING: -65°C TO 200°C.

VOLTAGE RATING: 600 VOLTS R.M.S.

STANDARD SPOOL PUT-UP: 1000 FT.

ORDERING INFORMATION: SPECIFY JAGUAR CATALOG NO. SUPPLIED WITH A WHITE JACKET AND THE FOLLOWING COLOR CODE: 
1-WHITE; 2-BLACK; 3-RED; 4-GREEN.*

AWG

NUMBER OF

CATALOG NO.

NOM. O.D.

CATALOG NO.

NOM. O.D.

SIZE

STRAND

CONDUCTORS

TAPED JACKET

(inches)

EXTRUDED JACKET

(inches)

30

7x38

1

JSTJ3007-1

.082

JSFJ3007-1

.072

30

7x38

2

JSTJ3007-2

.114

JSFJ3007-2

.104

30

7x38

3

JSTJ3007-3

.120

JSFJ3007-3

.110

28

7x36

1

JSTJ2807-1

.085

JSFJ2807-1

.075

28

7x36

2

JSTJ2807-2

.120

JSFJ2807-2

.110

28

7x36

3

JSTJ2807-3

.127

JSFJ2807-3

.117

26

19X38

1

JSTJ2619-1

.089

JSFJ2619-1

.079

26

19X38

2

JSTJ2619-2

.128

JSFJ2619-2

.118

26

19X38

3

JSTJ2619-3

.136

JSFJ2619-3

.126

26

19X38

4

JSTJ2619-4

.144

JSFJ2619-4

.134

24

19X36

1

JSTJ2419-1

.094

JSFJ2419-1

.084

24

19X36

2

JSTJ2419-2

.138

JSFJ2419-2

.128

24

19X36

3

JSTJ2419-3

.147

JSFJ2419-3

.137

24

19X36

4

JSTJ2419-4

.156

JSFJ2419-4

.146

22

19X34

1

JSTJ2219-1

.100

JSFJ2219-1

.090

22

19X34

2

JSTJ2219-2

.150

JSFJ2219-2

.140

22

19X34

3

JSTJ2219-3

.160

JSFJ2219-3

.150

22

19X34

4

JSTJ2219-4

.170

JSFJ2219-4

.160

20

19X32

1

JSTJ2019-1

.108

JSFJ2019-1

.098

20

19X32

2

JSTJ2019-2

.166

JSFJ2019-2

.156

20

19X32

3

JSTJ2019-3

.178

JSFJ2019-3

.168

20

19X32

4

JSTJ2019-4

.189

JSFJ2019-4

.179

18

19X30

1

JSTJ1819-1

.119

JSFJ1819-1

.109

18

19X30

2

JSTJ1819-2

.188

JSFJ1819-2

.178

18

19X30

3

JSTJ1819-3

.202

JSFJ1819-3

.192

18

19X30

4

JSTJ1819-4

.216

JSFJ1819-4

.206

16

19X29

1

JSTJ1619-1

.130

JSFJ1619-1

.120

16

19X29

2

JSTJ1619-2

.210

JSFJ1619-2

.200

16

19X29

3

JSTJ1619-3

.226

JSFJ1619-3

.216

14

19X27

1

JSTJ1419-1

.145

JSFJ1419-1

.135

14

19X27

2

JSTJ1419-2

.240

JSFJ1419-2

.230

12

19X25

1

JSTJ1219-1

.164

JSFJ1219-1

.154

12

19X25

2

JSTJ1219-2

.278

JSFJ1219-2

.268

10

37X26

1

JSTJ1037-1

.184

JSFJ1037-1

.174

*CONSULT FACTORY FOR OTHER STRANDINGS, COLOR CODES, AND NUMBER OF CONDUCTORS

The Jaguar PFTE shielded cable offers an ideal solution in comparison to a non-shielded cable. Shielded cables reduce the chance of dangerous surface discharge, help to prevent electrical interference and provide increased safety precautions. These cables protect insulated wiring, equipment and people from potential hazards. Jaguar shielded wire cables reduce the chance of damaging a cable that would otherwise need replacing, causing unnecessary work.

We maintain a large inventory of PFTE shielded cables. Simply let us know what you need and we will meet your shielded cable requirements. We have a strong, professional reputation for meeting our customer's needs in a short amount of time. We are the wire and cable experts you can trust to supply you with the best service and products for your specific application.

If you have any questions regarding our shielded cables or to request a Jaguar Industries catalog, please contact us directly by phone or complete the Ask Our Experts form on our Contact Us page. Our knowledgeable customer service specialists will be happy to assist you.


Contact Jaguar Industries

Email

Print this page

Other products and services from Jaguar Industries

06-Dec-2011

Heat Shrink Tubing - Polyolefin, PVC, PTFE & Electrical Shrink Tubing Manufacturers

It has been engineered for total compatibility with PVC jacketed wire and cable to insulate, identify, bundle, protect, repair and beautify in electronic, electrical and mechanical applications. It is made from thermoplastic material and includes polyolefin shrink tubing, PTFE shrink tubing and PVC shrink tubing, among others. It can also be used to repair wires, bundle wires together and to protect wires or small parts from minor abrasion.


06-Dec-2011

PTFE Wire - MIL-W-16878 TYPE E Insulated & Coated Hook Up Wires

PTFE coated wire is designed to operate in extreme conditions including high temperatures, high frequency, etc. PFTE wire choices such as MIL-W-16878 Type E have particularly lasting endurance and resilience. MIL-W-16878E, EE and ET PTFE insulated wires have applications that include military harnessing, power supply lead wire, appliance wiring and medical.


06-Dec-2011

PVC Insulated Wire - Jagflex Flexible Hook-Up Wire

It is often employed in telecommunication systems, toys, sports equipment and general wiring for electrical engineering and meets stringent demands in terms of high and ultra-high flexibility. This PVC insulated hook up wire can be used within enclosed electronic equipment. PVC insulated copper wire is an excellent choice for general use.


06-Dec-2011

Value-Added Services - Jaguar Industries

High speed twisting & planetary cabling equipmentis used to produce multiple conductor cables fromour huge stock of single conductor items. Wires can also be semi-stripped,leaving an easily removable "slug" of insulation as atemporary protection for the conductor. Laboratory physical & electrical test equipment is usedto assure compliance with customer specifications.