Scyon® Linea® Weatherboard | James Hardie

By: James Hardie  06-Dec-2011
Keywords: Product Warranty

Scyon® Linea® Weatherboard

With their deep shadow lines, Scyon® Linea® Weatherboard are virtually indistinguishable from timber, ideal for traditional and contemporary homes.






Weatherboards are designed to capture the deep shadow lines of traditional weatherboards. This makes them ideal for authentically replicating, re-cladding, or renovating older style homes. At the same time, Scyon Linea Weatherboard give architects and designers an extremely versatile cladding product that is increasingly being featured in a wide variety of stunning contemporary home designs - both on its own and in combination with other James Hardie lightweight cladding products such as Scyon





Manufactured from low-density fibre cement, Scyon Linea Weatherboard's inherent stability means that it can be painted in today’s popular darker colours making it particularly suitable for contemporary designs.


16mm thick bevel-back weatherboards creates strong shadow lines.

Three widths - 135mm, 150mm renovation profile and 180mm.

Tongue and groove ends for easy and unflashed off stud jointing reducing waste on site.

Pre-primed and has the ability to take darker colours.

Can be used to achieve bracing ratings.

Linea Weatherboard uses Ceramic Low Density (CLD®) technology that reduces the weight, without compromising the strength and durability.

Resistant to fire and damage from moisture and rotting when installed and maintained correctly.

Branz appraised for both direct fixed and cavity construction.

Codemark certified for direct fix and cavity construction.

Product warranty of 25 years.


16mm thick x 4200mm long x 135mm, 150mm or 180mm wide

Fire Resistance Rating

Up to a 90 minute fire resistance rated system can be achieved when installed as per the James Hardie Fire and Acoustic Technical Specification.

View Accessories

HardiBlade (Diamond tipped) Circular Saw Blade

185mm Diamond tipped circular saw blade. For use with all James Hardie products.
Selling Unit: 1
CODE: 300660

Inseal 3109 Foam Tape

Selling Unit: 16 x 9mm x 8 metres

Selling Unit: 5 x 3mm x 25 metres

CODE: 302324

Linea Weatherboard External Corner Soaker 90º

Soakers used on external corners.

Selling Unit: Box of 20

Size: 180mm, 150mm & 135mm

Available in Stainless steel, Aluminium and copper. Copper not available for 150mm.

Linea Weatherboard External Slim Box Corner 2700mm

Finishes internal corners. Aluminium chromate treated.
Selling Unit: 1

Linea Weatherboard Internal 'W' mould 90º & 135º 2700mm

Finishes internal corners. Aluminium chromate treated.
Selling Unit: 1
CODE: 301183 & 301184

Linea Weatherboard uPVC Box Corner Z Flashing 2700mm

For use behind box corners.
Selling Unit: 10
CODE: 301203

PVC External Corner Flashing 50mm x 50mm x 2.5 metres

Used with external corners.
Selling Unit: 10
CODE: 303745

Stainless Steel 316 Jolt Head Stainless Steel Nail 60mm 1kg Bag

For face fixing Linea Weatherboard.
Selling Unit: 1kg bag
CODE: 301233 & 301234

uPVC Vent Strip 75mm x 18mm x 3000mm

Used to provide protection from vermin entering cavity space.
Selling Unit: 25
CODE: 302420

Keywords: Product Warranty

Other products and services from James Hardie


HardieGlaze™ Lining | James Hardie

HardieGlaze Lining is also ideal in commercial applications such as shop linings, commercial kitchens with strict hygiene requirements, bathrooms and change-room facilities. This look changes up the wall by adding another dimension and shape utilising horizontal lines. Grande with its large elongated design gives an elegant minimalist look to your project. Ideal residential wet and dry area lining and as its name suggests.


Bracing Details | James Hardie

With the introduction of cavities and considering the new code requirements, James Hardie products are still suitable to achieve bracing values required for homes within the scope of NZS 3604. Bracing demand as required by NZS 3604 can easily be achieved by using James Hardie fibre cement sheets and Linea Weatherboards fixed to timber framing.


Fire and Acoustic Systems | James Hardie

In terms of the New Zealand Building Code requirements, fire rating is referred as FRR and is measured in minutes e.g. a FRR 30/30/30 means a fire rating for 30 minutes. This manual provides information about James Hardie two way fire and acoustic systems using timber or steel frames in residential or non residential construction. Separating walls in multi unit residential or commercial buildings. External walls close to boundaries.


Wet Area Construction | James Hardie

Installed correctly, James Hardie internal lining products can help prevent water or moisture from leaking to other parts of your home, protecting you from the hefty replacement costs of rotten timbers, walls and expensive tiles. It's important that the wet area construction is in accordance to current good practice and complies with clause E2 of the New Zealand Building Code.